How to drive out of warm water floor: expert advice

Anonim

How to drive out of warm water floor: expert advice

The work failure or normal functioning of the heating system is due to the accumulation of air bubbles.

In this regard, the question of how to drive out of warm water floors and improve performance, is quite popular with heating.

Such equipment costs considerable money, and to exclude possible costs, it is necessary to carry out pumping of a warm floor alone. Such technology does not require special skills, so it can be carried out independently.

The main reasons for the accumulation of air masses

How to drive out of warm water floor: expert advice

Often the air falls into the pipes when the system is deployed

The problem of the formation of air masses in modern heating systems is very urgent. It is faced with everything without exception owners of private and country houses.

One of the main reasons is the depressurization of the system itself, problems in the risers and the late replacement of individual devices. Often, air traffic jams are formed at the time of flushing and attaching individual elements to the heating radiator.

Education of such problems can occur when improper work aimed at installing or installing the heating system. In any case, this problem requires a speedy solution.

How to drive out of warm water floor: expert advice

Requires a planned air outlet before the first inclusion. The air must leave the heat-floor pipe system before heating such.

How to drive out of warm water floor: expert advice

Most heating systems are capable of functioning even after entering the air bubbles.

The circulation will be difficult, due to the appearance of bubbles in the radiator, and the warm floor will be heated in the event that air falls into its system.

A small thickness of pipes in aggregate with a feature of the system will not give her to heat up, and the floors will be cold.

You can get rid of the air and during the operation of the system, however it is much easier to do this before the onset of the first cold weather with an invisible mechanism. After some time, bubbles may appear again, so the system needs to be monitored and thoroughly check it, periodically blending the air.

Article on the topic: Whirlpool washing machines and malfunctions

How to drive out of warm water floor: expert advice

Remove air in the summer before starting the heating system

Education of air masses in a warm floor system

How to drive out of warm water floor: expert advice

For pumping system uses the pump

How to lower the air accumulated in the system will depend on the case that led to a similar result.

Some circumstances require speedy intervention, while others are not able to cause a strong damage system.

If the warm floor has been set with tangible drops, it is worth getting an additional pump for pumping the coolant.

It is recommended to install several automatic deliveries that will help to make air mass from the system. One is installed on the reverse highways, while the second must be applied.

Running the circulation pump will also help expel excess air. The more air accumulated, the louder will work the circulation pump. It is worth noting that the pumping system should be made at maximum speeds. This will significantly save time and will allow you to completely remove the air from the system. If this was recently pumped, but the air had already managed to gather again, the problem could be in the pump itself.

How to drive out of warm water floor: expert advice

How to drive out of warm water floor: expert advice

Air road

When the comb is installed, each contour overlaps alternately, while the air vent must open on each of them. It is necessary to lower the air gradually, so after cleaning the first contour the following opens. The descent is made in stages and only one contour should be opened at the moment of stewing.

If this procedure did not give the expected result, the next inclination should be done no earlier than in a few days.

To properly clean the system, a person should understand the combing device and understand the principle of its action. If the necessary knowledge is not available, you should seek help from specialists. Read more about the release of air, see this video:

Recently, separators, whose function is the automatic removal of air bubbles from the system, which significantly simplifies the further operation of the entire system.

Algorithm removal

At the highest points, gas is accumulated in the process of moving the coolant. When using a heap system as a device, with which the work is carried out, the comb or distributor performs. Otherwise, you will need to purchase more expensive equipment for the leading of air masses. Read more about pumping a warm floor, see this video:

Article on the topic: cross-stitch: how correctly, video and photos, how to sew learning, osinka do, value of processes from scratch

Below are the necessary actions to get rid of the heating system from air

  1. Most pumps are equipped with a stepped speed regulator. It is installed in the position "1", which will allow it to work on minimal revs. It will turn a little longer to download, but will allow you to completely remove the accumulated masses.

    How to drive out of warm water floor: expert advice

    Break all the contours except one

  2. The next stage is to overlap all the contours except one. This sequence must be observed throughout the operation on other sites.
  3. After removal of the air mass, the tap turns clockwise until complete closure.
  4. Since the engine will work on small revolutions, a similar procedure will need to be carried out repeatedly. The pump is turned off after the end of the first release of gases. Upon completion of all works, the crane opens again. Power is supplied, which will allow you to drive a coolant at low speed for a couple of minutes.
  5. This operation must be repeated at least 4 times. After overlapping the circuit with a tap, go to the next.

After completing all manipulations, the pressure rises to a normal working level.