Connecting PE Explorer to Outlets

Anonim

At the moment there is a lot of rules that are placed on the installation of sockets. It should also be remembered that the connection of electrical appliances should be carried out by branched, not a loop. Also to ensure security, you will need to connect the PE conductor to sockets.

Connecting PE Explorer to Outlets

PE conductor

Under the train in the energy sector, it is customary to count the segment of the wire that connects to the electrical wiring to create an electrical circuit. In this article you will learn how to connect the zero protective conductor to the outlet.

What is indicated in PUE

Information that is present in PUE rules can be explained as follows. The zero protective conductor in its entire length should be solid. The rules do not make the creation of a zero protective conductor from individual pieces of wire. Explain such a requirement is simple enough. When an emergency current is manifested in a socket or device through a protective conductor, there will be dangerous potential. His energy can continue to destroy unreliable compounds. In this case, all the devices that will be connected to the loop will remain unprotected.

Connecting PE Explorer to Outlets

Best PE Explorer Connection Option

Sometimes many electricians during wiring may make an error. They bind part of the sockets with one PE conductor without break. To do this, from a small section of the wire, experts will remove the insulation, and the metal core rolled the ring and wrap it with it. After that, the free end of the wire will be directed to the next socket. This method is not a branch and therefore it is impossible to use it.

Connecting PE Explorer to Outlets

To connect PE Explorer to the outlet correctly, you need to make a branch from the protective zero line through the installation box. To ensure a high-quality connection, you will need to use connectors that release Wago, Went or Scotchlok. Thanks to the use of such connections, you can connect sockets to a protected zero by a branch, and to phase with a loop. You can see this type of connection in the photo below.

Article on the topic: how to dismantle the old toilet

Connecting PE Explorer to Outlets

Connection Scheme PE Explorer to Outlet

If you study the connecting device in more detail, then it can be understood that it has small dimensions. Therefore, it can be hidden in the installation box. The wire connection will have the following form.

Connecting PE Explorer to Outlets

Connecting PE Explorer using connecting clip

To install the connector, you will also need to provide the amount of free space between the bottom of the installation box and the socket mechanism. It should be equal or to be a little more compressive thickness with connected wires.

Connecting PE Explorer to Outlets

Installation of sockets with PE Connection Explorer

Many experts report that there is another way of switching a zero protective conductor to sockets. For this, you will need to use an additional branch box. It is best installed next to the plug-in sockets.

Armature for mounting sockets and switches.

Read more